read-edid: EDID of multiple monitors

revision e4fb56c2741207beb389d73a4770e895f4c06c49

raw

phork0.txt

$ sudo get-edid -m 10 |parse-edid
1
0
This is read-edid version 3.0.1. Prepare for some fun.
Attempting to use i2c interface
No EDID on bus 0
No EDID on bus 1
No EDID on bus 2
No EDID on bus 3
No EDID on bus 4
No EDID on bus 5
No EDID on bus 7
No EDID on bus 9
3 potential busses found: 6 8 10
Will scan through until the first EDID is found.
Pass a bus number as an option to this program to go only for that one.
128-byte EDID successfully retrieved from i2c bus 6
Looks like i2c was successful. Have a good day.
Checksum Correct

Section "Monitor"
	Identifier "�
                     @"
	ModelName "�
                    @"
	VendorName "AUO"
	# Monitor Manufactured week 0 of 2012
	# EDID version 1.4
	# Digital Display
	DisplaySize 310 170
	Gamma 2.20
	Option "DPMS" "false"
	Modeline 	"M

$ sudo get-edid -b 8 |parse-edid
8
This is read-edid version 3.0.1. Prepare for some fun.
Attempting to use i2c interface
No EDID on bus 0
No EDID on bus 1
No EDID on bus 2
No EDID on bus 3
No EDID on bus 4
No EDID on bus 5
No EDID on bus 7
No EDID on bus 9
3 potential busses found: 6 8 10
Only trying 8 as per your request.
256-byte EDID successfully retrieved from i2c bus 8
Looks like i2c was successful. Have a good day.
Checksum Correct

Section "Monitor"
	Identifier "B19-5"
	ModelName "B19-5"
	VendorName "FUS"
	# Monitor Manufactured week 34 of 2008
	# EDID version 1.4
	# Digital Display
	DisplaySize 380 300
	Gamma 2.20
	Option "DPMS" "true"
	#Not giving standard mode: 1280x1024, 60Hz
	Modeline 	"Mode 0" 108.00 1280 1328 1440 1688 1024 1025 1028 1066 +hsync +vsync 
	Modeline 	"Mode 1" 189.83 2560 2608 2720 2968 1024 1025 1028 1066 +hsync +vsync 
	Modeline 	"Mode 2" 189.83 2560 2608 2720 2968 1024 1025 1028 1066 +hsync +vsync 
EndSection

$ sudo get-edid -b 10 |parse-edid
1
0
This is read-edid version 3.0.1. Prepare for some fun.
Attempting to use i2c interface
No EDID on bus 0
No EDID on bus 1
No EDID on bus 2
No EDID on bus 3
No EDID on bus 4
No EDID on bus 5
No EDID on bus 7
No EDID on bus 9
3 potential busses found: 6 8 10
Only trying 10 as per your request.
256-byte EDID successfully retrieved from i2c bus 10
Looks like i2c was successful. Have a good day.
Checksum Correct

Section "Monitor"
	Identifier "B19-5"
	ModelName "B19-5"
	VendorName "FUS"
	# Monitor Manufactured week 34 of 2008
	# EDID version 1.3
	# Digital Display
	DisplaySize 380 300
	Gamma 2.20
	Option "DPMS" "true"
	Horizsync 30-82
	VertRefresh 56-76
	# Maximum pixel clock is 140MHz
	#Not giving standard mode: 1280x1024, 60Hz
	Modeline 	"Mode 0" 108.00 1280 1328 1440 1688 1024 1025 1028 1066 +hsync +vsync 
EndSection

History